Analog-devices ADSP-2181 User Manual Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
ADSP-2181/ADSP-2183
REV. 0
–23–
ADSP-2181
Parameter Min Max Unit
Memory Read
Timing Requirements:
t
RDD
RD Low to Data Valid 0.5t
CK
– 9 + w ns
t
AA
A0-A13, xMS to Data Valid 0.75t
CK
– 10.5 + w ns
t
RDH
Data Hold from RD High 0 ns
Switching Characteristics:
t
RP
RD Pulse Width 0.5t
CK
– 5 + w ns
t
CRD
CLKOUT High to RD Low 0.25t
CK
– 5 0.25t
CK
+ 7 ns
t
ASR
A0-A13, xMS Setup before RD Low 0.25t
CK
– 6 ns
t
RDA
A0-A13, xMS Hold after RD Deasserted 0.25t
CK
– 3 ns
t
RWR
RD High to RD or WR Low 0.5t
CK
– 5 ns
ADSP-2183
28.8 MHz
Parameter Min Max Unit
Memory Read
Timing Requirements:
t
RDD
RD Low to Data Valid 0.5t
CK
– 9 + w ns
t
AA
A0-A13, xMS to Data Valid 0.75t
CK
– 12.5 + w ns
t
RDH
Data Hold from RD High 0 ns
Switching Characteristics:
t
RP
RD Pulse Width 0.5t
CK
– 5 + w ns
t
CRD
CLKOUT High to RD Low 0.25t
CK
– 5 0.25t
CK
+ 7 ns
t
ASR
A0-A13, xMS Setup before RD Low 0.25t
CK
– 6 ns
t
RDA
A0-A13, xMS Hold after RD Deasserted 0.25t
CK
– 3 ns
t
RWR
RD High to RD or WR Low 0.5t
CK
– 5 ns
w = wait states x t
CK
xMS = PMS, DMS, CMS, IOMS, BMS
CLKOUT
A0 – A13
D
t
RDA
t
RWR
t
RP
t
ASR
t
CRD
t
RDD
t
AA
t
RDH
DMS, PMS,
BMS, IOMS,
CMS
RD
WR
Figure 25. Memory Read
Page view 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 39 40

Comments to this Manuals

No comments